A wafer polishing witness sample should demonstrate a defined property under a defined process, with its identity preserved from receipt through the signed result. Agree who selects the sample, how representative it must be, which measurements apply and what the witness signs before starting the run. A polished piece alone cannot explain which criteria were demonstrated.
Hisemi lists precision lapping and polishing machines. Confirm the exact machine, substrate support and inspection arrangements in the trial plan. The acceptable wafer properties and measurement methods come from the project agreement. A machine capability description does not establish the result for a particular wafer, process or measurement map.
Agree the sample, measurement basis and attendance before processing.

Hisemi precision lapping and polishing equipment · Hisemi lapping and polishing machine range
Choose a sample that represents the purchase question
Specify substrate, size, incoming condition and relevant preparation or history. If a witness unit is intentionally a different material or geometry, state what it can establish and which actual-product checks are still due. Select and identify any comparison pieces in advance so the evaluation cannot quietly change after the result is known.
Agree how the witness sample will be tracked. Use the authorized carrier, position and identification procedure. Record movements and responsibility. Label supporting images and data by the actual sample and run rather than relying on a generic "before" or "after" filename.
Give each criterion a method and reviewer
| Criterion field | Agree before the run | Save at witness |
|---|---|---|
| Sample | Substrate, identity and representativeness | Actual carrier and condition |
| Process | Machine, fixture and authorized route | Executed configuration and deviations |
| Measurement | Property, instrument, points, units and exclusions | Raw results and method reference |
| Witness | Timing, authority and observation scope | What was observed or separately reviewed |
| Disposition | Acceptance and exception rules | Signed result and open items |
Thickness, thickness variation and surface finish address distinct requirements. Establish which ones apply and use the relevant method for each. If an observation belongs to a different face or measurement point, label it accordingly. Record unavailable points and use the project rule before calculating or interpreting a result.
Preserve the scope of the signed result
Make the witness record readable by a person who did not attend. Identify what was personally observed, what came from a supporting report and what remains pending. A result on one witness sample can support the stated demonstration. Document any separate sample, repeat or production confirmation required by the agreement.
If the process or fixture changes during the run, preserve both configurations and identify which pieces actually experienced each one. Agree what the change does to the original acceptance plan. Store raw outputs with the signed result so a later reviewer can verify which evidence supports the disposition.
Agree what the witness is expected to see
Split the demonstration into events with meaningful evidence. A witness can observe intake and the authorized process on a defined sample but may receive an instrument export afterward. State by event which person must be present and whether an approved equivalent can be used. A later signature should identify what was actually reviewed.
Choose measurable criteria with the relevant owners. A surface observation may require defined lighting or an applicable measurement method. A thickness criterion may specify a point pattern, units and valid exclusions. Confirm whether incoming values are necessary to understand the final result, then include those readings before the sample advances. A polished face and a dimensional map should identify the same run and piece.
Plan substitutions and repeats before the sample is handled
If a sample is damaged before the run, retain its identity and condition and follow the agreed rule for substitution. Have the parties agree whether a replacement demonstrates the same requirement. When a test point cannot be measured, preserve the available readings and state the applicable rule. Keep material, method and disposition distinct so missing evidence is not silently replaced by a convenient observation.
For a tightly scheduled supplier visit, write down which work can be witnessed in person, which results will be generated later and who receives them. Ask the supplier and buyer to agree a completion date for every required report. That helps the customer decide whether the inspection can support dispatch or leaves an open acceptance item.
A complete witness record should allow a customer engineer to find the approved criterion, actual sample, executed process and applicable result. Attach the measurement condition and evidence that supports each decision. For a future procurement discussion, bring the machine and fixture references as well. A later buyer can compare the planned job to the configuration that actually ran.
Sample selection should resolve what the customer actually needs to learn from the witness run. A single readily available wafer might allow a demonstration of the loading and handling route. The customer may still need a different substrate and approved measurement plan to evaluate its product. Put both purposes on the agreement and identify how each will be demonstrated. Review the practical limits on sample quantity and handling before the witness date.
Ask the metrology owner to prepare an evidence map before production staff handle the sample. Include coordinates, orientation, units and permissible exclusions for the required measurements. Give the supplier enough information to identify the actual locations. If the incoming and final methods differ, document the intended comparison and its limitations under the agreed plan. Retain the raw results so a reviewer can reproduce the approved interpretation rather than relying on a chart prepared for the meeting.
Specify how the customer will learn about any deviation. For example, if a planned measurement position is inaccessible or a fixture must change before the run, contact the authorized reviewer and record what happened. Depending on the agreement, the demonstration may continue with a defined limitation or require a repeat. Store the original planned run and the actual accepted scope. Do not rename the revised case so it appears to be the originally agreed one.
Close the file with a brief comparison between required evidence and received evidence. Identify the actual review result and any pending report by item. Preserve the individual approvals if different owners are responsible for process capability and the sample's condition. Give the customer the actual record when the wafer is returned. The shipment should identify the carrier and sample without requiring the recipient to interpret the supplier's internal production labels.
Ask the customer to define why the witness is required before writing the sample list. If the concern is interpreting the agreed final surface, the methods and reference piece need early attention. If the concern is handling or loading a particular wafer, the authorized carrier and geometry may be central. Write those questions visibly beside the selected pieces. The sample list should show how each piece addresses a specific requirement and which outcomes remain outside its scope.
A comparison piece can help explain the evaluation, provided its role is written down before the run. Retain a separate sample where the agreement requires a future reference. Mark where each receiving, processing and measurement record will live. If a witness receives images or data after the visit, ask them to verify that the sample and run references match the signed scope. Record when the subsequent evidence was actually reviewed.
Give the supplier a time window for which observers will be present and what information can be shown under the parties' agreement. Assign responsibility for measuring, recording data and resolving questions. If the observation moves to another session, preserve that schedule change with the actual executed run. The trial should show what happened, who saw it and which acceptance criteria remained pending. An unresolved report can remain open with a named owner until it is formally reviewed.
For the returned wafer, ask the recipient to confirm carrier and sample identity against the actual report. Keep the handling arrangement, orientation and condition recorded. If subsequent measurement uses a different method, save it as another identified observation and agree how it relates to the witness result. A documented comparison supports continued technical review without blurring what the parties originally witnessed.
Before the witness visit, confirm what raw records can be delivered and how the customer will associate them with each sample. A report can be complete on paper while leaving its images or measurement exports hard to identify. Ask the witness to verify one linkage before the session closes and record any delivery due after the visit. Include the people responsible for returning the sample and reviewing later evidence. The signed acceptance file should state what remains open and who can close it under the agreed procedure.
During planning, identify how the buyer will evaluate a sample damaged in transit or found unsuitable during incoming inspection. Preserve the condition and obtain the authorized decision before processing. Name which representative piece would replace it under the agreed trial, and save the change to the witness list and associated data requirements.
Witness sample questions
Can an alternative substrate be used?
It may support a defined demonstration if the agreement allows it. State which actual-product requirements remain outside that result.
Who selects the witness pieces?
Agree the authority, selection method and sample count in advance. Keep the actual identifiers in the record.
Are photos sufficient for dimensional acceptance?
Use the approved measurement method for the required property. Retain images for identity, orientation or appearance where relevant.
What if the witness cannot attend a measurement?
Identify the actual observers and supporting records. Ask the parties to decide whether remote or later review satisfies the agreement.
Does a successful sample release future production?
Follow the agreed evidence requirements. Record the exact scope of the witness decision and any additional production checks.
What should Hisemi receive before the trial?
Send substrate, geometry, incoming condition, target properties, measurement plan and witnessing scope. Identify handling constraints and required deliverables.
Define the witness plan with Hisemi