Center Thickness and TTV on a Wafer Acceptance Report

Nov 18, 2026

Leave a message

Jack
Jack
Hisemi editorial team

WAFER METROLOGY

Center thickness is one result at the defined center of a wafer. Total thickness variation, or TTV, describes the difference between the highest and lowest thickness values over the specified measurement area or sampling pattern. Present both when both matter to acceptance. A part can meet a center target and still exceed the allowed variation elsewhere.

Hisemi lists a Wafer Lapping Polishing Machine with multiple plate options and stated wafer sizes. Those catalogue entries identify a candidate machine, while a measured wafer acceptance report concerns the exact workpiece and agreed method. Define the quality area, measurement setup and criteria before comparing results. A successful development sample is evidence about its own recorded conditions.

Report both decisions

Center thickness and valid maximum-minus-minimum assess different acceptance criteria.

Hisemi wafer lapping and polishing machine

View the related product or series · Compare the second product or supplier reference

Wafer center thickness vs TTV: define the measurement scope

Identify the wafer, side, reference mark, orientation, method, instrument and units. Specify which region counts for acceptance and how any edge exclusion is handled. Decide whether a defined map, line or other method will be used. Have the technical owner confirm which points or readings form the TTV calculation. Keep excluded or invalid readings visible as applicable with the reason, without adding them to the accepted statistic contrary to the method.

A number without the measured scope is difficult to reproduce. Two reports can use the same title while using different sampling patterns or conditions. Even on the same part, a broader area can reveal a thicker or thinner region outside the original scope. Preserve the original maps and approved coordinates when a later report has a different purpose.

Report field Definition to capture Why it matters
Center thickness Defined coordinate, units, method and result It describes one point under the method
TTV Valid maximum minus valid minimum in the defined scope It describes variation across that scope
Map Included area, excluded area and sample reference Shows how the result was obtained
Retest Method, reason and original record Makes the decision traceable

Work the calculation with an example

Assume the center measurement is 725 μm and the valid points in a hypothetical approved map include a minimum of 721 μm and maximum of 729 μm. The reported variation for those points is 8 μm. If a center-only requirement is 724 to 726 μm, the center would meet the example requirement. A separate hypothetical TTV limit of 5 μm would not be met. These values illustrate the reporting distinction and are not machine capability or suggested limits.

Give each requirement its own status and applicable authority. Do not average the center and TTV outputs into a blanket pass. The technical owner should decide what the hypothetical issue would require: another measurement under the same scope, investigation of the process condition or a different workpiece decision.

Put the approval next to the evidence

Match the initial and finished reports by actual sample and method. If a handling or instrument change makes comparison uncertain, document it. A useful acceptance report identifies which measurements apply at each stage and whether finish or geometry scope is separate. Keep the exact metric and result together so quoting and receiving teams can find what has been established.

Put a map beside every variation statistic that controls release

A reader should be able to see which points map to the cited minimum and maximum. Ask the lab to identify locations and preserve the map output used for calculation. Where the sample is circular or has an edge reference, require a direction convention so a second operator can find the same point. Distinguish the center location from any nominal center approximation in the method. If the actual setup cannot access the agreed point, ask the technical owner how to disposition the report.

State whether the math uses a defined area or an explicitly agreed sample pattern. A different pattern may include a feature the original did not. Do not rewrite the difference as a process improvement unless the sampling conditions are comparable. If the new metrology instrument has different behavior or settings, preserve the instrument and method revision. Ask the responsible reviewer to decide whether the populations can be compared and what evidence is needed.

Give every map an identification and date. It can be useful to draw the excluded edge zone and annotate a special handling or measurement condition, while following the approved rules for interpreting each point. A sample can meet the center requirement while showing an unacceptable range in the zone the buyer cares about. Keep those decisions as separate thresholds so a reviewer can see exactly what passed and which issue remains open.

Use an acceptance row to separate arithmetic from judgment

Start the row with the actual sample and criterion. Then enter the readings, valid min and max, result and applicable limit. Identify the source of the criterion and who signs it off. The arithmetic alone cannot say whether the defined scope is the correct one. If the wrong area was used, retain the original output, record the weakness and seek an authorized repeat rather than silently recalculating a different set.

For example, a trial report might have a centered reading inside the customer's bounds but an agreed variation measure outside its own limits. The header can state "center requirement met, TTV open" instead of using one green mark. If an unusually high value appears near an excluded boundary, request review of the actual coordinates and method before deciding how to treat it. The drawing and instrument evidence should provide enough detail to reproduce the judgment.

A useful summary can also identify what a later process needs to know. A buyer concerned with the next operation may need allowable geometry, surface requirements or handling conditions independently of the values reported here. Maintain this distinction in the technical package. A finished sample acceptance decision may combine several approved records without pretending they are measurements of one property.

Ask the supplier which report the demonstration will produce

Provide the actual workpiece, approved geometry and required measurement evidence. Ask the supplier which machine and configuration the proposal covers, and how the lab will identify original readings, map and finished analysis. If the process finishes a demonstration coupon rather than a production wafer, describe the scope accordingly. A simple note can show whether the material and size supplied match the parts planned for production.

Discuss how the buyer can review unusual or missing information. If one report uses a changed measuring range or another support method, obtain a clear record. Preserve the sample orientation and instrument information with any before-and-after comparison. Attach accepted examples for the supplier and buyer when ordering additional equipment or asking for a trial on another material. The note should tell staff which records need updating when the workpiece changes.

At handover, name the authorized owner for process changes and the person who releases the measurement evidence. Keep machine eligibility, sample outcome and routine production approval visible as separate items. An accepted sample at stated conditions can be useful without becoming a universal precision claim. Sales can accurately refer to the released scope and technical staff can find the original proof when the project changes.

Compare how a map becomes evidence in two different situations. A central process setup may track the center value to see whether work has approached a target. An acceptance plan may still require the valid maximum and minimum across an agreed pattern. Give each purpose a name and do not quietly transfer a process observation into the acceptance record. If the same instrument serves both purposes, identify which data were actually collected and which conclusions the project permits. Have a second authorized reviewer reproduce the arithmetic using the valid points and the recorded criterion. A common error during report preparation is to type the center measurement into the variation column when another file is unclear. Clear units and an explicit arithmetic field can help catch this. If identifying a point depends on a map orientation, prove that the reader can find it using the supplied reference. On a sample order, agree who owns the data output and whether a specific file format or marked drawing is needed at handover. After a later process change, preserve the accepted map and report what has changed. This keeps the original approval meaningful and gives the relevant reviewer a basis to select any required repeat. Include a place for fields that do not apply or remain unverified so absence of data cannot be confused with a measurement of zero. Close each criterion on the conditions under which it was evaluated.

Questions before accepting a report

Can I calculate TTV from the center alone?

No. It requires the valid maximum and minimum from the stated measurement scope.

Should a map cover the complete physical wafer?

Use the agreed quality area and method and record any edge exclusions.

Does a tighter center target guarantee flatness?

No. Record distinct metrics and their approved definitions.

What if the method changed?

Preserve both reports and let the responsible metrology owner assess comparability.

Should a rejected point be removed silently?

Follow the approved method and record why it was excluded or repeated.

What should the machine inquiry contain?

Send actual wafer size, material, measurement scope, targets and required evidence.

Request a sample report from Hisemi

Send the approved workpiece description and measuring requirements. Ask for the applicable machine configuration and a sample of the reports available at each stage.

Contact Hisemi Technology